Indirect Sterilization
TB Units
| These newly designed fixtures
control tuberculosis, as well as other airborne viruses,
mold spores and microorganisms.
Designed to reduce upper-air contamination, TB germicidal
sterilizers feature an adjustable louver to allow unlimited
direction of the ultraviolet rays while protecting personnel
and providing maximum germicidal energy. The units are
constructed of 304 stainless steel with an alzak aluminum
reflector and cover 75, 200 and 300 square feet respectively.
They mount seven feet above the floor and use 10,000-hour
hardglass slimline quartz lamps. Relamping requires
only disconnecting the power and lowering the hinged
front louver. Models are shipped assembled and include
a grounded power cord, pull-chain switch, slimline ultraviolet
lamp and louver.
Technical Data Sheet
|
|
| Model
# |
TB12W |
TB24W |
TB36W |
| Lamp# |
GML060 |
GML
325 |
GML005 |
| Lamp
Life |
10,000
hours |
10,000
hours |
10,000
hours |
| Lamp
Intensity |
50
uW/CM2 |
100
uW/CM2 |
175
uW/CM2 |
| Air
Movement |
Convection |
Convection |
Convection |
| Electrical |
120V,
60Hz, 3 Amp |
120V,
60Hz, 3 Amp |
120V,
60Hz, 3 Amp |
| Construction |
304
Stainless Steel |
304
Stainless Steel |
304
Stainless Steel |
| Sq.
Ft. Coverage |
75
sq. ft. |
200
sq. ft. |
300
sq. ft. |
| Lamp
Replacement |
Yearly |
Yearly |
Yearly |
Return to Indirect Sterilization |
|
|
|
|
|
|

|
|