OR Package 2.0 Components

All American Ultraviolet UVC germicidal fixtures include motion + heat sensors, on-board lamp intensity monitors, high-efficiency electronic transformers, and 12,000-hour UVC lamps.

10" Touchscreen Controller

The OR-CCU is the brain of the American Ultraviolet Operating Room Package.

  • Constantly communicates with all UV germicidal fixtures in the OR
  • Built-in safety features
  • Procedure and disinfection modes
    • Procedure mode
      • Used during orthopedic surgery
      • Reduced intensity; untimed cycle
      • Reduces post-op infection rates
    • Disinfection mode
      • Used before and/or after procedures
      • Full intensity; timed cycle
      • Can run daily preprogrammed cycle
  • All cycle data is saved to the onboard hard drive and is available for staff review. Data can also be downloaded via the USB port on the bottom of the CCU. The Intelligent controller records:
    • Date
    • Time
    • Case ID #
    • Cycle type
    • UVC intensity levels
    • Fixture functionality
    • System performance data

Direct Surface Mounted Fixtures

OR-SM-36 fixturesOR-SM-36 fixtures are direct UVC germicidal fixtures used for surface and wound site disinfection before, during, and after the procedure, making the American Ultraviolet OR Package a very smart choice for Operating Room disinfection

  • Lowered intensity during orthopedic procedures
  • Full power during disinfection cycles and before and after procedures
  • Preset daily timed disinfection cycles

The advantage of using ceiling mounted ultraviolet light fixtures in the OR, rather than a mobile device, is that the fixtures can be spaced out to create a more consistent pattern of energy - more angles provides better coverage. 

OR-SM-36 fixturesA typical installation will have 8-10 OR-SM-36 surface mounted fixtures on the ceiling:

  • Four (4) fixtures mounted above the table: two parallel to the sides & two parallel to the head and foot
  • Remaining fixtures evenly spaced around the Operating Room for consistent energy distribution

The goal of this configuration is to lay down an even energy footprint that floods the room with UV disinfection light and eliminates, or at least minimizes, any shadowed areas. Mobile units currently on the market are limited in their energy footprint, and they also require multiple positions in order to have a similar impact.


Indirect Wall Mounted Fixtures

OR-SM-36 fixturesOR-WM-36 UVC germicidal fixtures confine UVC rays to a narrow beam, directed across the upper portion of the room, for upper air treatment. Beam width and height are controlled with louvers that create a powerful, concentrated beam of germicidal UVC energy, resulting in maximum intensity and increased safety.

  • Installed on adjacent walls at least 7½ - 8 feet off of the floor. 
  • Create a high-intensity intersection of energy in the upper portion of the room, above the table, to enhance the laminar flow system.
  • Indirect style fixtures are designed for upper air irradiation and are left at full power during use. 
  • Lamps and louvers easily removable for maintenance.
Indirect Wall Mounted Fixtures

Door Barrier Fixtures

Door Barrier Fixtures OR-DB fixtures confine UVC rays to a narrow beam, creating a "curtain" of energy in all doorways. Beam width and height are controlled with louvers that create a powerful, concentrated beam of germicidal UVC energy, resulting in maximum intensity and increased safety.

  • Installed above all doorways in operating theater.
  • Staff entering or exiting the space during the procedure will pass through the UV barrier, which will provide a high intensity dose of UVC, adding to the cumulative levels achieved while in the space.
  • Beam width and depth are controlled with louvers that create a powerful, concentrated beam of germicidal UVC energy, resulting in maximum intensity and increased safety.
  • Wider doorways can be equipped with multiple units, mounted in tandem, to span the entire width of the passage.
  • Available in 24" and 36" fixture widths to accommodate typical doorway sizes found in operating rooms.
  • Lamps and louvers easily removable for maintenance.

UVC Radiometer

UVC RadiometerEach OR Package includes a Radiometer that measures the intensity of UVC light energy delivered to the surgical site and communicates with the controller, and fixtures, to deliver the appropriate energy level during procedures.


UV In Use Warning Signs

OR-SIGNOR-SIGN safety signs that come with the OR Package are illuminated warning signs designed to alert personnel entering the operating theater that direct UV disinfection light is being used inside the room. Any time the UV fixtures in the room are energized, the warning sign(s) illuminate with a "CAUTION UV LIGHT ON" message.

  • Mounted outside the OR next to or above all of the doors
  • Any lamps lit = warning signs illuminated 

In addition to this bold visual indicator, each and every UVC fixture in the room is an "intelligent" fixture with its own Motion + IR sensor.  If any fixture were to "see" motion or sense heat in the space during a full disinfection cycle, all of the fixtures will immediately shut down, and the fault will be recorded as part of the data logging. 

  • Motion + IR sensors are active in the Disinfection Cycle modes (both manually initiated and timed cycles)
  • Motion + IR sensors are deactivated in the Procedure mode as the room is occupied. 
  • In either mode, when the lamps are lit, the warning sign(s) will be illuminated. 

Safety Face Shields

  • OR-SIGNAmerican Ultraviolet provides one dozen UV-resistant, optically-clear, full face shields with each Operating Room Package. When used in conjunction with a head sock, this piece of PPE provides complete coverage for the head and neck.
  • As with all ultraviolet equipment, PPE such as protective clothing and eyewear are required when UV exposure is possible. Personnel should never look directly into any of the fixtures without proper eye protection. 

Staff Training

Full staff training from a qualified, experienced trainer about proper usage and maintenance is included with the American Ultraviolet OR Package. A comprehensive Operation & Maintenance Manual is also provided with each package. Though the OR Package is user-friendly, you can be certain we remain committed to making sure all of your users are comfortable with how to operate and maintain the OR Package

To learn more about the OR Package, and other healthcare products from American Ultraviolet that will help reduce the spread of HAI's and SSI's,, please visit our technical library where you can download and print literature.

 

Reference 1. “Ultraviolet Radiation: Its Beneficial Effect On The Operating Room Environment And The Incidence of Deep Wound Infection Following Total Hip and Total Knee Arthropolasty.” J. Drennan Lowell, M.D., Ruth B. Kundsin, PH.D. (Full article available upon request).

Reference 2. “Ultraviolet Lighting During Orthopaedic Surgery and the Rate of Infection.” Merrill A. Ritter, Emily M. Olberding and Robert A. Malinzak. Journal of Bone & Joint Surgery 2007;89:1935-1940 doi:10.2106/JBJS.F.01037 (Click here to review full article).